SafeAir - Safe smoke extraction solutions from the basement to the roof!
We can offer you the world’s largest range of mechanical smoke extraction solutions. With our wall, roof, radial, axial and induction fans we have mastered every form of smoke extraction, whatever the application.
Smoke extract roof fans RDM 56/57
Stylish smoke extract roof fan within the genovent-rang.
- Fan and accessories tested to EN 12101-3
Certificate of EC conformity:
RDM 56: 0036 CPD RG01 01
RDM 57: 0036 CPD RG01 02 - Suitable for smoke extraction in the event of fire
RDM 56: +400°C – 120min.
RDM 57: +600°C – 120min.
Continuous standard ventilation up to +80°C - Volume flow up to 57,000 m³/h
- Snow load class requirements SL 1000 to DIN EN 12101-3
- Assigned for mounting over heated and unheated rooms
Vertical discharge and swirl free, casing made of aluminium, integrated discharge back draught damper, side panel can be removed, centre structure can be swiveled, motor lead cable protected by a cable duct, loose mounting plate for isolator provided.
> Get the documentation here ...
> Start fan selection via proSELECTA II
Smoke extract wall fans RWM
Stylish smoke extract wall fan for integration into exterior housing facades.
- Fan and accessories tested to EN 12101-3
Certificate of EC conformity: 0036 CPD RG01 03 - Suitable for smoke extraction in the event of fire +600°C – 120min.
Continuous standard ventilation up to +80°C - Volume flow up to 37,000 m³/h
Horizontal air discharge, casing made of galvanized sheet steel, motor separated from main air stream, motor lead cable loose. mounting frame (accessory) available for easy installation into building front.
> Get the documentation here ...
> Start fan selection via proSELECTA II
Smoke extract centrifugal fans with direct drive REM BU
Direct driven smoke extract centrifugal fan with single inlet and flanged standard IEC motor.
- Fan and accessories tested to EN 12101-3
Certificate of EC conformity: 0036 CPD RG 01 05 - Suitable for smoke extraction in the event of fire +600°C – 120min.
Continuous standard ventilation up to +80°C - Volume flow up to 35,000 m³/h
Casing and impeller welded and coated. IEC motor out of the main air stream.
Optional with insulation housing REM BI (for installation inside of buildings – outside room with fire risk)
> Get the documentation here ...
> Start fan selection via proSELECTA II
Smoke extract centrifugal fans with belt drive RER 13/17
Belt driven smoke extract centrifugal fan with single inlet.
- Fan and accessories tested to EN 12101-3
Certificate of EC conformity:
RER 13: 0036 CPD RG01 06
RER 17: 0036 CPD RG01 07 - Suitable for smoke extraction in the event of fire +400°C – 120min.
Continuous standard ventilation up to +80°C - Volume flow up to 150,000 m³/h
RER 13: Casing made of sheet steel, welded and coated
RER 17: Lock formed casing made of galvanized sheet steel base frame, belt drive and motor are an integral part of the supply.
Optional with insulation housing (for installation inside of buildings – outside room with fire risk)
> Get the documentation here ...
> Start fan selection via proSELECTA II
Smoke extract axial flow fan with direct drive SLCS
Axial smoke extract fan with a tested conflagration gas motor.
- Fan and accessories tested to EN 12101-3
Certificate of EC conformity: 0086 CPD 493001 - Suitable for smoke extraction in the event of fire
SLCS 300°C – 120min.
SLCS 400°C – 120min.
Continuous standard ventilation up to +40°C - Volume flow up to 65,000 m³/h
Casing with spun flange, welded from sheet steel, hot dipped galvanized finish.
Die casting aluminium axial impeller with aerofoil profiled blades
Electric motors, certified at 300 degs.C for 120 mins, IP 55 enclosure, Class H, Insulation and Temperature Classification not exceeding Class F as standard - at current operation and at normal
ambient temperature.
> Get the documentation here ...
> Start fan selection via proSELECTA II
Smoke extract induction jetfans AGM/RGM


Jetfan induction fan system, the intelligent solution of smoke extraction for underground car parks and passages.
- Fan and accessories tested to EN 12101-3
Certificate of EC conformity:
AGM 01/11: 0036 CPD RG 01 09
AGM 02/12: 0036 CPD RG 01 10
RGM 91: 0036 CPD RG 01 11 - Suitable for smoke extraction in the event of fire +300°C – 120min.
Continuous standard ventilation up to +40°C
AGM 06/16 and RGM 96 for ventilation of CO-gases up to +40°C - Thrust up to 52 N (Series: AGM and RGM 91-0600)
Thrust up to 75 N (Series: RGM 90-0610)
AGM 01/02/06: Air flow in direction of motor (pressure) - not reversible.
AGM 11/12/16: Air flow in direction of motor (pressure/suction) - reversible
Casing made of galvanized sheet steel and equipped with silencer at both ends. Air flow straightener. Adjustable guide vanes. Axial fan impeller made of cast aluminum. Certified motor for smoke gases, protection IP 55, ISO H, maximum operation allowed to ISO F.
RGM 91/96: Radial Jetfan in a particularly low design, casing made of galvanized sheet metal, suction side with guard, pressure side with integrated guide vanes, centrifugal impeller with backward curved blades of steel, welded and coated, certified motor for smoke gases, protection IP 55 with heat-resistant connection with terminal box fitted on metal fan casing.
> Get the documentation here ...
> Start fan selection via proSELECTA II